PRM Series Autonics Cylindrical Inductive Proximity Sensors Specifications
— These sensors operate at 15 – 30VDC, detect metal objects, have IP67 protection, and are suitable for industrial use.

Autonics PRM Series Cylindrical Inductive Proximity Sensor Switch(DC-2-Wire-Type)

图片

RFQ Now For 10% Off!

Please enable JavaScript in your browser to complete this form.

Technical Features

Analog output type, supports 1 – 10 V, 4 – 20 mA output
Red indicator light for easy confirmation of power status
IP67 protection rating (IEC standard)

Products Specifications

Model namePRM☐18-5D☐PRM☐18-8D☐PRM☐30-10D☐PRM☐30-15D☐
Power supply voltage18-30 VDC (ripple P-P: ≤10%), usable voltage range: 16.5-33 VDC
Sensing distance1-5 mm2-8 mm2-10 mm3-15 mm
Linear distance1-3.5 mm2-5.5 mm2-7 mm3-10 mm
Standard sensing target: Iron18 × 18 × 1 mm25 × 25 × 1 mm30 × 30 × 1 mm45 × 45 × 1 mm
Sensing side diameterØ 18 mmØ 30 mm
Current consumptionBelow 20 mA (excluding load)
Response frequency 01)200 Hz200Hz
Influence of temperatureWithin ±5% of sensing distance at 20°C ambient temperature
IndicatorPower indicator (red)
Repeat accuracy±5% (Linear distance, for output deviation to ideal linear curve, max linear output deviation is ±5% or less of F.S.) 02)
Linearity±3%
Protection circuitSurge protection circuit, reverse polarity protection circuit
Insulation resistance≥50 MΩ (500VDC megger)
Dielectric strength1,500 VAC ~ 50/60 Hz 1 minute (between all terminals and case)
Vibration10 ~ 55 Hz (period 1 minute) amplitude 1mm X, Y, Z directions for 2 hours each
Shock500 m/s² (≈ 50 G) X, Y, Z directions 3 times each
Resistive loadDC (voltage output type) 4.7 kΩ / DC (current output type) below 300 Ω
Voltage influence 03)Within ±0.5% F.S. of the output at rated voltage, for ±10% change in power supply voltage at room temperature.
Ambient temperature-25 ~ 70°C, storage: -30 ~ 80°C (no freezing, no condensation)
Ambient humidity35 ~ 95% RH, storage: 35 ~ 95% RH (no freezing, no condensation)
Protection degreeIP67 (IEC standard)
ConnectionCable outgoing type / Cable outgoing connector type 04)
Cable specificationSensing side Ø 18 mm, Ø 30 mm: Ø 5 mm, 3-core
Conductor specificationØ 5mm cable: AWG 22 (0.08 mm, 60-core), insulation outer diameter: Ø 1.25 mm
Connector specificationM12 connector
MaterialGeneral cable (black): Polyvinyl chloride (PVC), Case/Nut: Brass, nickel-plated, Washer: Iron, nickel-plated, Sensing side: PBT
Approvalsimage 44
Product weight≈ 110 g≈ 58 g≈ 170 g≈ 122 g
1. The response frequency is an average value. The measurement conditions are: using the standard sensing target, the distance to the target is twice the size of the standard sensing target, and the setting distance is 1/2 of the sensing distance.
2. Linearity is only applicable for the linear distance range. Beyond the linear distance, the output deviation is within ±5% F.S.
3. In an environment with a temperature of 20°C, a power supply voltage of 24 VDC, and a load of 4.7 kΩ (cable type)/300Ω (connector type), the standard sensing target is used as the basis.
4. Cable outgoing type: 2 m, Cable outgoing connector type: 300 mm.

Distance-Output Characteristics

image1
image 76

Influence of Mutual Interference and Surrounding Metal

■ Mutual Interference

As shown in the figure below, when two or more proximity switches are installed face-to-face or side-by-side, malfunctions may occur due to frequency interference. The installation spacing must meet the requirements of the table below.

image 40
[Face-to-face installation]
image 42
[Side-by-side installation]

■ Influence of Surrounding Metal

If metal is present around the proximity switch, it may cause malfunctions such as poor resetting. To prevent malfunctions, the installation spacing must meet the requirements of the table below.

image 43

(Unit: mm)

Sensing side
_______________
Item
Ø 18 mmØ 30 mm
Flush typeNon-flush typeFlush typeNon-flush type
A30486090
B36546090
l014015
Ød18543090
m15243045
n27544590

Allowable Installation Torque

When tightening the nut, please use the provided washer. The allowable nut torque is the value when using the attached washer and inserting as shown in the figure below.

image 23
Sensing face
——————Strength
Ø 18 mmØ 30 mm
Flush typeNon-flush typeFlush typeNon-flush type
Front-end dimension26 mm12 mm
Front-end torque14.7 N·m49 N·m
Rear-end torque14.7 N·m78.4 N·m